Thermal movement analysis
Axial and radial growth over the full operating range including upset and cooldown, differential movement between shell and insulation, and the resulting strain at every interruption.
Insulation does not fail where the calculation was wrong; it fails where the system was not allowed to move. Steel grows, the insulation does not grow with it, and the cladding tears, the sealant splits and the vapour barrier opens at exactly the points nobody detailed. ERATHERM designs the movement: expansion and contraction joint positioning, support ring and standoff sizing, band and clip arrangement, and the thermal movement analysis behind them, for insulated vessels, columns, tanks and high-temperature piping. We work worldwide, in EPC-level English, to ASME and EN practice.

Each package below starts from the temperature range and the geometry, and ends in a drawing that a fabricator can weld and a crew can install.
Axial and radial growth over the full operating range including upset and cooldown, differential movement between shell and insulation, and the resulting strain at every interruption.
Joint spacing, joint construction, filler selection and the sequencing of joints against nozzles, supports and stiffeners, so the movement is taken where it was designed to be taken.
Ring spacing, section, material and attachment designed for insulation dead load, cladding load, wind and personnel load, with the hot face temperature taken into account.
Standoffs, bands, clips and spacers for vessels, columns and tanks, sized to carry the load while limiting the conductive path they create.
Lap direction, fixing spacing, sliding joints, flashing and termination details that let the cladding move without opening the weather and vapour barrier.
Heat loss and cold spot assessment for every support, ring and attachment, fed back into the thickness calculation instead of being ignored.
Attachments to a pressure-retaining shell are reviewed against the vessel code and the manufacturer's requirements; welded attachments are referred to the equipment designer.

A carbon steel line at 450 °C grows roughly 5 mm per metre. Over a 30 metre run that is 150 mm of movement, and the insulation system has to absorb all of it without transferring load into the cladding or the sealant.
Where no expansion joint is drawn, the system finds its own: the cladding buckles at the first restraint, the lap opens, water enters and corrosion under insulation starts in the one place where it is hardest to inspect.
Produced under your document control procedure, in EPC-level English, revision controlled.
Axial and radial growth by line and equipment, with the temperature cases stated.
Spacing, section, material, attachment detail and load case summary.
Construction, filler, sequence and position marked on the equipment layout.
Type, spacing and quantity by equipment, with the conductive penalty noted.
Laps, fixings, sliding joints, flashings and terminations.
Heat loss and surface temperature at each support type, fed back into the thickness basis.

Support attachment to pressure equipment is governed by the vessel code and by the manufacturer's drawings. We work to the project's code set, most commonly ASME Section VIII for vessel attachments, ASME B31.3 or B31.1 for piping interfaces, and EN 13445 or EN 13480 where the European set applies.
Insulation construction detailing follows the project specification, CINI practice or the plant's own standard, and the reference used is stated in the drawing title block.
The movement problem changes shape with the geometry. Each family is detailed against the mechanism that actually drives it.
Axial growth over long runs; joint spacing and sliding cladding laps govern.
Ring load accumulation down the shell and wind load on the cladding govern the ring design.
Saddle interfaces and differential movement between shell and support govern.
Roof and shell junction movement, settlement and large-diameter cladding panels govern.
Large thermal range, panel stiffening and duct distortion govern the attachment design.
Contraction rather than expansion; cold bridging at every support becomes the dominant penalty.

In cryogenic service the shell shrinks away from the insulation, and any detail that relies on compression to stay closed opens up. Contraction joints, slip layers and oversized sleeves have to be designed for the cooldown, not for the installed condition.
Every support is simultaneously a thermal short. The design problem is to carry the load with the smallest conductive path, and then to account for the path that remains in the heat leak budget.

Since the company was founded we have never used a subcontractor on any job. The application is carried out by our own qualified and certified personnel, with our own tools and equipment.
A support detail that cannot be installed from the available scaffolding, or a joint that needs a tool that does not fit between two lines, is not a detail. Every drawing we issue has been built by the same organisation that drew it.
Industrial Insulation Catalogue
Engineering scope, calculation and documentation services, material families and application capability in a single document.
ERATHERM works as an engineering partner for operators, EPC contractors and equipment manufacturers. Calculation, design, documentation and specification work is delivered remotely under the client's document control procedure; inspection, site supervision and application teams are mobilised to site.
From the calculated growth over the design temperature range and the movement capacity of the joint construction chosen, checked against the positions of nozzles, supports and stiffeners. It is not taken from a fixed spacing rule, because the governing temperature range differs from line to line.
The project's code set governs. Attachments to pressure equipment are most commonly reviewed against ASME Section VIII or EN 13445 for vessels and ASME B31.3, B31.1 or EN 13480 for piping. Insulation construction detailing follows the project specification, CINI practice or the plant standard, and the reference is stated on the drawing.
We design the insulation support arrangement and the loads it imposes. Welded attachments to a pressure-retaining shell are referred to the equipment designer or manufacturer for code acceptance, and our drawings state that interface explicitly.
Yes. Where cladding is tearing, sealant is splitting or corrosion under insulation is appearing at supports, we survey the installation, identify the restrained points and issue a repair detail set with the movement calculation behind it.
It depends on the ring section, the spacing and the hot face temperature, and it is calculated rather than estimated. On high-temperature equipment the support path can account for a significant share of the total loss, which is why we feed it back into the thickness calculation.
Equipment and line list with sizes and materials, the design and operating temperature range, the general arrangement or isometrics, any vessel drawings showing existing attachments, and the project specification where one exists.
The detailed pages behind each part of the design.
With the equipment list, the operating range and the general arrangement we will calculate the movement, define the joint and support strategy and issue the detail set your scope needs.