Eratherm İzolasyon A.Ş.
Expansion · Supports · Movement Analysis

Insulation Thermal Expansion and Support Ring Design

Insulation does not fail where the calculation was wrong; it fails where the system was not allowed to move. Steel grows, the insulation does not grow with it, and the cladding tears, the sealant splits and the vapour barrier opens at exactly the points nobody detailed. ERATHERM designs the movement: expansion and contraction joint positioning, support ring and standoff sizing, band and clip arrangement, and the thermal movement analysis behind them, for insulated vessels, columns, tanks and high-temperature piping. We work worldwide, in EPC-level English, to ASME and EN practice.

Expansion joint positioningSupport ring sizingThermal movement analysisCladding attachment design
Insulation support ring, expansion joint and cladding attachment design on process equipment
1,000,000+ m²Completed insulation application
20+ yearsEngineering and site experience
15,000+ MWPower plant insulation experience
3 continentsProject delivery
Scope

Six design packages for movement and support

Each package below starts from the temperature range and the geometry, and ends in a drawing that a fabricator can weld and a crew can install.

01

Thermal movement analysis

Axial and radial growth over the full operating range including upset and cooldown, differential movement between shell and insulation, and the resulting strain at every interruption.

02

Expansion joint positioning

Joint spacing, joint construction, filler selection and the sequencing of joints against nozzles, supports and stiffeners, so the movement is taken where it was designed to be taken.

03

Support ring sizing

Ring spacing, section, material and attachment designed for insulation dead load, cladding load, wind and personnel load, with the hot face temperature taken into account.

04

Standoff and clip design

Standoffs, bands, clips and spacers for vessels, columns and tanks, sized to carry the load while limiting the conductive path they create.

05

Cladding attachment design

Lap direction, fixing spacing, sliding joints, flashing and termination details that let the cladding move without opening the weather and vapour barrier.

06

Thermal bridge assessment

Heat loss and cold spot assessment for every support, ring and attachment, fed back into the thickness calculation instead of being ignored.

Pressure boundary interface

Attachments to a pressure-retaining shell are reviewed against the vessel code and the manufacturer's requirements; welded attachments are referred to the equipment designer.

Thermal expansion damage at an insulation joint on high-temperature piping
Why it fails

The joint that was never drawn is the one that opens

A carbon steel line at 450 °C grows roughly 5 mm per metre. Over a 30 metre run that is 150 mm of movement, and the insulation system has to absorb all of it without transferring load into the cladding or the sealant.

Where no expansion joint is drawn, the system finds its own: the cladding buckles at the first restraint, the lap opens, water enters and corrosion under insulation starts in the one place where it is hardest to inspect.

  • Growth calculated over the real operating range, not nominal
  • Joint spacing derived from the movement, not from a rule of thumb
  • Cold service contraction treated with the same rigour
  • Restraints identified before the detail is issued
Deliverables

What you receive from a movement package

Produced under your document control procedure, in EPC-level English, revision controlled.

Movement calculation

Axial and radial growth by line and equipment, with the temperature cases stated.

Support ring drawings

Spacing, section, material, attachment detail and load case summary.

Expansion joint details

Construction, filler, sequence and position marked on the equipment layout.

Standoff and clip schedule

Type, spacing and quantity by equipment, with the conductive penalty noted.

Cladding detail set

Laps, fixings, sliding joints, flashings and terminations.

Thermal bridge summary

Heat loss and surface temperature at each support type, fed back into the thickness basis.

Engineering review of insulation supports against ASME and EN practice
Standards

Designed against code, not against habit

Support attachment to pressure equipment is governed by the vessel code and by the manufacturer's drawings. We work to the project's code set, most commonly ASME Section VIII for vessel attachments, ASME B31.3 or B31.1 for piping interfaces, and EN 13445 or EN 13480 where the European set applies.

Insulation construction detailing follows the project specification, CINI practice or the plant's own standard, and the reference used is stated in the drawing title block.

  • Vessel and piping code interfaces respected explicitly
  • Project specification taken as governing where it is stricter
  • Material selection matched to the hot face temperature
  • Drawings issued in your own title block and numbering
Equipment types

Six equipment families and what governs each

The movement problem changes shape with the geometry. Each family is detailed against the mechanism that actually drives it.

High-temperature piping

Axial growth over long runs; joint spacing and sliding cladding laps govern.

Vertical columns and towers

Ring load accumulation down the shell and wind load on the cladding govern the ring design.

Horizontal vessels and drums

Saddle interfaces and differential movement between shell and support govern.

Storage tanks

Roof and shell junction movement, settlement and large-diameter cladding panels govern.

Flue gas ducts and stacks

Large thermal range, panel stiffening and duct distortion govern the attachment design.

Cryogenic equipment

Contraction rather than expansion; cold bridging at every support becomes the dominant penalty.

Cryogenic contraction joint and support detailing on an insulated vessel
Cold service

Contraction is the harder half of the problem

In cryogenic service the shell shrinks away from the insulation, and any detail that relies on compression to stay closed opens up. Contraction joints, slip layers and oversized sleeves have to be designed for the cooldown, not for the installed condition.

Every support is simultaneously a thermal short. The design problem is to carry the load with the smallest conductive path, and then to account for the path that remains in the heat leak budget.

  • Contraction joints designed for the full cooldown range
  • Slip layers and oversized sleeves where movement is restrained
  • Low-conductivity standoffs and load-bearing inserts evaluated
  • Residual thermal short carried into the heat leak budget
Qualified application team installing insulation supports and cladding on site
Constructibility

Drawn by people who have installed it

Since the company was founded we have never used a subcontractor on any job. The application is carried out by our own qualified and certified personnel, with our own tools and equipment.

A support detail that cannot be installed from the available scaffolding, or a joint that needs a tool that does not fit between two lines, is not a detail. Every drawing we issue has been built by the same organisation that drew it.

  • No subcontractors; our own qualified and certified personnel
  • Details checked against real access and scaffolding
  • Prefabrication opportunities identified at drawing stage
  • Field feedback fed into the next revision

Industrial Insulation Catalogue

Engineering scope, calculation and documentation services, material families and application capability in a single document.

Open the 2026 catalogue

Working worldwide

ERATHERM works as an engineering partner for operators, EPC contractors and equipment manufacturers. Calculation, design, documentation and specification work is delivered remotely under the client's document control procedure; inspection, site supervision and application teams are mobilised to site.

  • Europe, the Middle East, Asia, Africa and the Americas
  • EPC-level deliverable documentation
  • Client document control procedure
  • Remote engineering and site mobilisation
Frequently asked

Movement design and support detailing

How is expansion joint spacing decided?

From the calculated growth over the design temperature range and the movement capacity of the joint construction chosen, checked against the positions of nozzles, supports and stiffeners. It is not taken from a fixed spacing rule, because the governing temperature range differs from line to line.

Which codes do you work to?

The project's code set governs. Attachments to pressure equipment are most commonly reviewed against ASME Section VIII or EN 13445 for vessels and ASME B31.3, B31.1 or EN 13480 for piping. Insulation construction detailing follows the project specification, CINI practice or the plant standard, and the reference is stated on the drawing.

Do you design welded attachments to the shell?

We design the insulation support arrangement and the loads it imposes. Welded attachments to a pressure-retaining shell are referred to the equipment designer or manufacturer for code acceptance, and our drawings state that interface explicitly.

Can you review an existing installation?

Yes. Where cladding is tearing, sealant is splitting or corrosion under insulation is appearing at supports, we survey the installation, identify the restrained points and issue a repair detail set with the movement calculation behind it.

What does a support ring cost in heat loss?

It depends on the ring section, the spacing and the hot face temperature, and it is calculated rather than estimated. On high-temperature equipment the support path can account for a significant share of the total loss, which is why we feed it back into the thickness calculation.

What data do you need to start?

Equipment and line list with sizes and materials, the design and operating temperature range, the general arrangement or isometrics, any vessel drawings showing existing attachments, and the project specification where one exists.

Send us the temperature range and the geometry

With the equipment list, the operating range and the general arrangement we will calculate the movement, define the joint and support strategy and issue the detail set your scope needs.